Water hardness in South Holland, IL
Water in South Holland is very hard, with a median of 232 mg/L (13.6 grains per gallon) across 23 monitoring sites within 10 miles.
South Holland tap water at a glance
- HardnessVery hard (232 mg/L, 13.6 gpg, local measurements). Water softeners are common at this level.Size a water softener →
- PFAS1 found in EPA testing; every result with a federal limit was at or below it.PFAS results →
- Lead pipesThe water system reported 1,139 lead service lines.Check your own pipe →
- Violations2 health-based violations since 2016.What they were →
Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?
What 232 mg/L means at home
- Water softener: Scale build-up is likely. A water softener is commonly used to protect plumbing, water heaters and appliances.
- Dishwasher: set the water hardness to about 13.6 gpg (13 °dH), which is a high or maximum hardness setting, with dishwasher salt if your model takes it.
- Kettles and coffee makers: descale every 1–2 months with citric acid or vinegar.
- Laundry and soap: hard water reduces lather, so you may need more detergent, or a softener.
- Water heater: flush the tank once a year to clear sediment and scale.
Size a softener for your home → Hard water and your water heater →
Where the number comes from
Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it
Water softener and dishwasher calculator for South Holland
Prefilled with South Holland's measured local hardness of 232 mg/L (13.6 gpg). If your water bill or utility report gives a different number, enter it instead.
Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter
PFAS in South Holland tap water
The City of South Holland water system is the main public water system for South Holland. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 8 samples taken Jul 2024 – Apr 2025. 1 PFAS was detected.
| Chemical | Highest result | Detected in | EPA limit |
|---|---|---|---|
| PFBA perfluorobutanoic acid | 7.3 ppt | 1 of 8 samples | — |
Other water systems serving parts of South Holland
| Water system | PFAS detected | Highest PFOA / PFOS | Tested |
|---|---|---|---|
| Harvey serves over 10,000 people | None detected | — | Sep 2023 – Jun 2024 |
What these PFAS levels mean → Which water filters remove PFAS →
Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology
Lead pipes in South Holland
The City of South Holland water system reported 8,235 service lines (the pipes connecting homes to the water main) in its inventory. 1,139 are lead and 53 are galvanized lines that must be replaced, and 204 are still of unknown material.
EPA's 2024 lead rule requires most water systems to replace these lines within 10 years, starting in November 2027 (the rule is being challenged in court). Ask the City of South Holland water system whether your address is on its list.
Other water systems serving parts of South Holland
| Water system | Service lines | Total |
|---|---|---|
| Harvey | 16 lead · 0 galvanized · 7,922 unknown | 8,199 |
How to tell if your home has a lead pipe → Lead pipes in every state →
As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology
South Holland drinking water violations
EPA records show 2 health-based violations for the City of South Holland water system since 2016, all since resolved or closed. The most recent began in Jun 2022. It also had 6 monitoring or reporting violations (a required test or report was missed or late), which on their own do not mean the water exceeded a limit.
| Contaminant or rule | Type | Violations | Most recent | Status |
|---|---|---|---|---|
| Lead and Copper Rule corrosion control, testing and notification requirements for lead | Treatment requirement not met | 2 | Jun 2022 | Resolved/closed |
Other water systems serving parts of South Holland
| Water system | Health-based violations | Monitoring/reporting |
|---|---|---|
| Harvey | None | 5 |
Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology
Monitoring sites closest to South Holland
| Site | Type | Distance | Median | Samples | Years |
|---|---|---|---|---|---|
| Thorn Creek illinois epa (State) | River/Stream | 2.1 mi | 389 mg/L | 24 | 2000–2002 |
| NORTH CREEK BELOW 183RD STREET NEAR THORNTON, IL USGS Illinois Water Science Center | Stream | 2.9 mi | 282 mg/L | 1 | 2000 |
| North Creek illinois epa (State) | River/Stream | 2.9 mi | 309 mg/L | 3 | 2001 |
| Little Calumet River illinois epa (State) | River/Stream | 3.7 mi | 157 mg/L | 3 | 2001 |
| Deer Creek illinois epa (State) | River/Stream | 4.3 mi | 280 mg/L | 3 | 2001 |
| DEER CREEK NEAR GLENWOOD, IL USGS Illinois Water Science Center | Stream | 4.3 mi | 239 mg/L | 1 | 2000 |
Water hardness in towns near South Holland
| Town | Distance | Median | Class |
|---|---|---|---|
| Dolton | 2 mi | 217 mg/L | Very hard |
| Harvey | 3 mi | 232 mg/L | Very hard |
| Calumet City | 3 mi | 239 mg/L | Very hard |
| Riverdale | 4 mi | 224 mg/L | Very hard |
| Lansing | 4 mi | 252 mg/L | Very hard |
| Homewood | 4 mi | 239 mg/L | Very hard |
| Markham | 5 mi | 232 mg/L | Very hard |
| Hazel Crest | 5 mi | 236 mg/L | Very hard |
| Blue Island | 6 mi | 217 mg/L | Very hard |
| Chicago Heights | 6 mi | 278 mg/L | Very hard |
Cook County
South Holland is in Cook County, where the median is 252 mg/L (very hard) across 63 sites.
See all of Cook County →South Holland, IL water: common questions
Do I need a water softener in South Holland?
Very likely. Water measured around South Holland is 13.6 gpg (232 mg/L, measured locally), above 10.5 gpg (180 mg/L), where softeners are common. For a 3-person home that regenerates weekly, that means a softener of about 24,000 grains.Size it for your household →
Who supplies South Holland's drinking water?
The main public water system serving South Holland in EPA records is South Holland. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →
Do I need a water filter in South Holland?
It depends on what you want to remove. In South Holland, EPA testing found PFBA in the main system; filters certified to NSF/ANSI 53 or 58 for PFOA and PFOS reduction can lower PFAS; the system reports 1,139 lead service lines; if your home has one, a filter certified to remove lead is the usual step until the line is replaced; the system had 2 health-based violations since 2016, for the Lead and Copper Rule; the utility's annual report says what was done about them. A water softener is not a filter.Filters that remove PFAS →
Hardness scale
What to read next
- Do you need a water softener?Water here is very hard; size a softener with our calculator.
- Which water filters remove PFAS?EPA tests found 1 PFAS in South Holland's main water system.
- How to tell if your home has a lead pipe1,139 lead service lines are reported here.
- Hard water and your water heaterHow scale affects your water heater and how often to flush.