How we measure water hardness

Every number on this site comes from public laboratory measurements or from official reports published by water utilities. Nothing is estimated by AI or copied from marketing material.

Two kinds of numbers

  • Utility-reported tap water values. For major cities we use the hardness published by the city's water utility, linked on the page, with its year. When a utility reports a range, we show the range and use its midpoint as the headline number.
  • Measured source water. Everywhere else, we summarise laboratory measurements of local groundwater and surface water, which is what feeds most local supplies.

United States data

We use the Water Quality Portal, run jointly by the US Geological Survey (USGS) and the Environmental Protection Agency (EPA). It combines results from USGS, EPA and hundreds of state, tribal and local agencies. We take every result for Hardness, Ca, Mg reported in mg/L as calcium carbonate, sampled from 2000 onward. The current US dataset (built 2026-11-21) has 1,119,112 samples from 102,688 monitoring sites.

Canada data

We combine Environment and Climate Change Canada's National Long-term Water Quality Monitoring data for every major river basin with Ontario's Provincial (Stream) Water Quality Monitoring Network and Provincial Groundwater Monitoring Network. We use total hardness as CaCO3; where a sample reports only dissolved calcium and magnesium, we calculate hardness as 2.497 × Ca + 4.118 × Mg. The Canadian dataset (built 2026-11-18) has 59,519 samples from 1,122 monitoring sites.

Canadian monitoring sites are much sparser than in the US, so a municipality uses all sites within 25 km and otherwise falls back to its census division ("region") median. Regions and municipalities are Statistics Canada 2021 census divisions and subdivisions.

Which sites count

We include wells, springs, streams, rivers, lakes, reservoirs and public water supply facilities. We exclude estuaries, ocean and beach sites, wetlands, wastewater, storm sewers, mines and similar locations that don't reflect drinking water sources, including sites whose names identify them as sewers, outfalls, wastewater, landfills or leachate even when they are typed as streams. Values above 2,000 mg/L (brines) and results flagged as below detection are excluded.

How areas are summarised

  • Site: the median of all of its samples, so a site sampled 500 times counts the same as a site sampled once.
  • County, region, state or province: the median of all site medians inside the boundary.
  • Town (US): the median of all sites within 10 miles (16 km) of the town's center. If fewer than three sites are that close, we show the county median and say so on the page.
  • Municipality (Canada): the median of all sites within 25 km, when at least two exist; otherwise the region median, stated on the page.

Hardness classes

We use the USGS classification: soft (0–60 mg/L), moderately hard (61–120), hard (121–180) and very hard (over 180). One US grain per gallon (gpg) equals 17.12 mg/L; one German degree (°dH) equals 17.85 mg/L.

Limits

Source-water figures can differ from tap water where a utility softens, blends or imports water from far away. Your utility publishes an annual report with exact tap values (in the US, the Consumer Confidence Report). Private wells can vary a lot over short distances, so a home test kit is the best check.

PFAS ("forever chemicals") in US tap water

PFAS results come from EPA's fifth Unregulated Contaminant Monitoring Rule (UCMR 5). Between 2023 and 2026, about 10,300 public water systems tested treated drinking water for 29 PFAS. That covers every system serving more than 3,300 people, plus a representative sample of smaller ones. We use EPA's final published dataset and show the highest single result for each chemical, in parts per trillion (ppt, equal to nanograms per liter).

  • Matching water systems to towns. Each system reports the ZIP codes it serves. We link a system to a town when one of those ZIP codes overlaps the town's land area (Census 2020 ZIP-to-place relationship), keeping only systems in the same state. A system is called the town's main system when its name contains the town's name (for example "City of Phoenix" for Phoenix), or when we verified it against the utility's own website. Otherwise we list all the systems serving parts of the town, because ZIP codes alone can't tell which one supplies a particular street.
  • Limits. We show the individual limits from EPA's 2024 drinking water rule: 4 ppt for PFOA and PFOS, and 10 ppt for PFHxS, PFNA and GenX (HFPO-DA). Compliance is judged on a running annual average from 2029 (EPA has proposed allowing some systems until 2031), so a single result above a limit is not by itself a violation. In 2026 EPA proposed keeping the PFOA and PFOS limits and withdrawing the limits for PFHxS, PFNA and GenX; we mark those with an asterisk until the proposal is final. PFBS has no individual limit (only the rule's mixture "hazard index", which we don't calculate).
  • Not detected means below EPA's minimum reporting level for that chemical (2–20 ppt depending on the chemical), not necessarily zero.
  • Lithium was also part of UCMR 5. It is not a PFAS, so it is not shown here.

Lead service lines

Lead pipe counts come from the service line inventories that community water systems must keep under EPA's lead rules, as reported by states to EPA's Safe Drinking Water Information System (SDWIS service line inventory). For each water system we show the number of lines reported as lead, galvanized requiring replacement (galvanized lines that are or were downstream of lead), lead status unknown, and non-lead. Towns are matched to water systems the same way as for PFAS (see above).

  • Unknown lines have not been identified yet. We never count them as lead or as safe.
  • Systems that have not reported any categories yet are shown as "not reported".
  • Inventories change as utilities inspect lines, so we update the numbers each quarter EPA publishes.

Drinking water violations

Violations come from EPA's Safe Drinking Water Information System, as published in the ECHO SDWA data download. For each water system matched to a town (see PFAS above) we count violations whose noncompliance period began in the last ten years, counting each violation once.

  • Health-based violations are the three kinds EPA marks as health-based: a contaminant above its maximum contaminant level (MCL), a disinfectant above its maximum residual disinfectant level (MRDL), or a treatment technique requirement not met.
  • Monitoring and reporting violations mean a required sample or report was missed or late. We count them separately, because on their own they do not mean the water exceeded a limit.
  • Status is EPA's: resolved, archived (more than five years old), or still open (addressed or unaddressed).
  • Contaminant and rule names are shown in plain English with EPA's original name underneath where it helps.

ZIP code lookup

The ZIP code search uses the Census Bureau's 2020 ZIP Code Tabulation Areas, which approximate USPS ZIP codes. For each ZIP we list the towns with their own page that cover at least 5% of its land, the main county, and, where no town has its own page, the small towns in that ZIP with their water system (the same records as the county page tables). Numbers are the same as on the linked pages. A ZIP code can cross town and water system boundaries, so check your water bill to see which utility serves you. Some PO-box-only ZIP codes have no area and are not found.

Population and boundaries

US names, locations and populations come from the US Census Bureau (2023 Gazetteer and population estimates; 2010 Census for unincorporated places), with Census 2023 county boundaries. Canadian geography and populations come from Statistics Canada's 2021 Census.

How pages and guides are made

Town, county and state pages are generated from the datasets above; guides are written with AI assistance from the sources they cite. Details: how we make our content.

Corrections

Spotted something wrong? Tell us and we'll check it against the source.