Water hardness in Burke Centre, VA
Water in Burke Centre is soft, with a median of 55 mg/L (3.2 grains per gallon) across 80 monitoring sites within 10 miles.
Burke Centre tap water at a glance
- HardnessSoft (55 mg/L, 3.2 gpg, local measurements). A water softener isn't needed.Water heater care →
Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?
What 55 mg/L means at home
- Water softener: A water softener is generally not needed. Soft water rarely causes scale.
- Dishwasher: set the water hardness to about 3.2 gpg (3.1 °dH), which is the lowest hardness setting (or softener off).
- Kettles and coffee makers: descaling every 3–6 months is usually enough.
- Laundry and soap: soap lathers easily and detergent goes further.
- Water heater: routine flushing every 2–3 years is typically fine.
Where the number comes from
Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it
Water softener and dishwasher calculator for Burke Centre
Prefilled with Burke Centre's measured local hardness of 55 mg/L (3.2 gpg). If your water bill or utility report gives a different number, enter it instead.
Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter
PFAS in Burke Centre tap water
Burke Centre is served by more than one water system. These systems supply ZIP codes in Burke Centre and were tested for PFAS ("forever chemicals") in EPA's nationwide UCMR 5 study. Check your water bill to see which one is yours.
Water systems serving Burke Centre
| Water system | PFAS detected | Highest PFOA / PFOS | Tested |
|---|---|---|---|
| Fairfax County Water Authority serves over 10,000 people | PFPeA, PFBA, PFHxA +5 more | 7.4 / 5.7 ppt | Mar 2024 – Feb 2025 |
What these PFAS levels mean → Which water filters remove PFAS →
Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology
Lead pipes in Burke Centre
Burke Centre is served by more than one water system. Their service line inventories, as reported to EPA:
Water systems serving Burke Centre
| Water system | Service lines | Total |
|---|---|---|
| Fairfax County Water Authority | 16 lead · 2 galvanized · 115 unknown | 290,219 |
How to tell if your home has a lead pipe → Lead pipes in every state →
As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology
Burke Centre drinking water violations
Burke Centre is served by more than one water system. Health-based violations recorded by EPA since 2016:
Water systems serving Burke Centre
| Water system | Health-based violations | Monitoring/reporting |
|---|---|---|
| Fairfax County Water Authority | None | 0 |
Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology
Monitoring sites closest to Burke Centre
| Site | Type | Distance | Median | Samples | Years |
|---|---|---|---|---|---|
| Rt. # 645 (Burke Lake Rd) VIRGINIA DEPARTMENT OF ENVIRONMENTAL QUALITY | River/Stream | 1.4 mi | 28 mg/L | 9 | 2001–2003 |
| 52U5R USGS Maryland Water Science Center | Well | 2.4 mi | 15 mg/L | 1 | 2014 |
| LONG BRANCH AT OLLEY LANE NR FAIRFAX, VA USGS Virginia Water Science Center | Stream | 2.9 mi | 34 mg/L | 22 | 2021–2023 |
| Rt. # 643 (Henderson Rd) VIRGINIA DEPARTMENT OF ENVIRONMENTAL QUALITY | River/Stream | 3.2 mi | 48 mg/L | 5 | 2001–2002 |
| LONG BRANCH NEAR ANNANDALE, VA USGS Virginia Water Science Center | Stream | 3.8 mi | 67 mg/L | 45 | 2020–2023 |
| Rt. # 620 (Braddock Rd) VIRGINIA DEPARTMENT OF ENVIRONMENTAL QUALITY | River/Stream | 4 mi | 74 mg/L | 302 | 2001–2026 |
Water hardness in towns near Burke Centre
| Town | Distance | Median | Class |
|---|---|---|---|
| Kings Park West | 2 mi | 60 mg/L | Soft |
| Fairfax Station | 2 mi | 60 mg/L | Soft |
| Burke | 2 mi | 50 mg/L | Soft |
| Wakefield | 4 mi | 56 mg/L | Soft |
| West Springfield | 4 mi | 49 mg/L | Soft |
| Fairfax | 4 mi | 62 mg/L | Moderately hard |
| Newington Forest | 5 mi | 48 mg/L | Soft |
| Fair Oaks | 6 mi | 64 mg/L | Moderately hard |
| Annandale | 6 mi | 53 mg/L | Soft |
| Springfield | 6 mi | 48 mg/L | Soft |
Fairfax County
Burke Centre is in Fairfax County, where the median is 60 mg/L (moderately hard) across 107 sites.
See all of Fairfax County →Hardness scale
What to read next
- Water hardness converterConvert mg/L to grains per gallon or °dH for your dishwasher.