Water hardness in Brookfield, WI

Water in Brookfield is very hard, with a median of 335 mg/L (19.6 grains per gallon) across 29 monitoring sites within 10 miles.

126% harder than the Wisconsin median (148 mg/L) 14th hardest of 97 Wisconsin towns Population 41,884
335mg/L
19.6 grains per gallon
Very hard

Brookfield tap water at a glance

  • HardnessVery hard (335 mg/L, 19.6 gpg, local measurements). Water softeners are common at this level.Size a water softener →
  • PFAS2 found in EPA testing; every result with a federal limit was at or below it.PFAS results →
  • Lead pipesNo lead service lines reported.Details →
  • ViolationsNo health-based violations since 2016.EPA record →

Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?

What 335 mg/L means at home

  • Water softener: Scale build-up is likely. A water softener is commonly used to protect plumbing, water heaters and appliances.
  • Dishwasher: set the water hardness to about 19.6 gpg (18.8 °dH), which is a high or maximum hardness setting, with dishwasher salt if your model takes it.
  • Kettles and coffee makers: descale every 1–2 months with citric acid or vinegar.
  • Laundry and soap: hard water reduces lather, so you may need more detergent, or a softener.
  • Water heater: flush the tank once a year to clear sediment and scale.

Where the number comes from

Monitoring sites29
Lab samples191
Sample years2000–2024
Middle 50% of sites300–419 mg/L
Groundwater (wells, springs)490 mg/L · 10 sites
Surface water (rivers, lakes)305 mg/L · 19 sites

Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it

Water softener and dishwasher calculator for Brookfield

Prefilled with Brookfield's measured local hardness of 335 mg/L (19.6 gpg). If your water bill or utility report gives a different number, enter it instead.

Softener capacity needed (at least)–
Dishwasher setting–set your dishwasher's water hardness to this
Sodium added by softening–

Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter

PFAS in Brookfield tap water

Town of Brookfield San Dist 4 is the main public water system for Brookfield. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 6 samples taken May 2025 – Nov 2025. 2 PFAS were detected.

ChemicalHighest resultDetected inEPA limit
PFBS
perfluorobutane sulfonic acid
7.1 ppt 1 of 6 samples —
PFBA
perfluorobutanoic acid
6.3 ppt 1 of 6 samples —

Other water systems serving parts of Brookfield

Water systemPFAS detectedHighest PFOA / PFOSTested
Brookfield Water Utility
serves over 10,000 people
PFBS, PFPeA, PFHxA +1 more — Jan 2023 – Jul 2025
Waukesha Water Utility
serves over 10,000 people
None detected — Feb 2023 – Aug 2023

What these PFAS levels mean → Which water filters remove PFAS →

Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology

Lead pipes in Brookfield

Town of Brookfield San Dist 4 reported 2,105 service lines (the pipes connecting homes to the water main) in its inventory. It reported no lead or galvanized lines requiring replacement.

0lead (0%)
0galvanized requiring replacement
0unknown material (0%)
2,105not lead (100%)

Other water systems serving parts of Brookfield

Water systemService linesTotal
Brookfield Water Utility0 lead · 0 galvanized · 485 unknown13,817
Waukesha Water Utility0 lead · 0 galvanized · 0 unknown20,519

How to tell if your home has a lead pipe → Lead pipes in every state →

As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology

Brookfield drinking water violations

EPA records show no health-based violations for Town of Brookfield San Dist 4 since 2016. It also had 1 monitoring or reporting violation (a required test or report was missed or late), which on their own do not mean the water exceeded a limit.

Other water systems serving parts of Brookfield

Water systemHealth-based violationsMonitoring/reporting
Brookfield Water Utility749
Waukesha Water Utility16028

Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology

Monitoring sites closest to Brookfield

SiteTypeDistanceMedianSamplesYears
7N20E-16.3E
USGS Illinois Water Science Center
Well 0.8 mi419 mg/L12001
UNDERWOOD CREEK AT JUNEAU BLVD AT ELM GROVE, WI
USGS Wisconsin Water Science Center
Stream 2.2 mi335 mg/L22017–2018
7N20E-18.1c
USGS Illinois Water Science Center
Well 2.5 mi540 mg/L32000–2021
UNDERWOOD CREEK AT WAUWATOSA, WI
USGS Wisconsin Water Science Center
Stream 3.7 mi343 mg/L122004–2005
7N19E-36.7g
USGS Illinois Water Science Center
Well 4.5 mi624 mg/L32000–2021
MENOMONEE RIVER ABOVE CHURCH ST AT WAUWATOSA, WI
USGS Wisconsin Water Science Center
Stream 5.3 mi300 mg/L22017–2018

Water hardness in towns near Brookfield

TownDistanceMedianClass
Wauwatosa4 mi 253 mg/LVery hard
West Allis6 mi 270 mg/LVery hard
Pewaukee6 mi 378 mg/LVery hard
New Berlin6 mi 305 mg/LVery hard
Menomonee Falls7 mi 335 mg/LVery hard
Sussex7 mi 335 mg/LVery hard
Waukesha7 mi 360 mg/LVery hard
Milwaukee8 mi 138 mg/LHard
Greenfield9 mi 258 mg/LVery hard
Greendale10 mi 253 mg/LVery hard

Waukesha County

Brookfield is in Waukesha County, where the median is 268 mg/L (very hard) across 50 sites.

See all of Waukesha County →

Wisconsin

The statewide median is 148 mg/L (hard) from 1,102 sites.

Wisconsin hardness map →

Brookfield, WI water: common questions

Do I need a water softener in Brookfield?

Very likely. Water measured around Brookfield is 19.6 gpg (335 mg/L, measured locally), above 10.5 gpg (180 mg/L), where softeners are common. For a 3-person home that regenerates weekly, that means a softener of about 34,000 grains.Size it for your household →

Who supplies Brookfield's drinking water?

The main public water system serving Brookfield in EPA records is Town of Brookfield San Dist 4. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →

Do I need a water filter in Brookfield?

It depends on what you want to remove. In Brookfield, EPA testing found PFBS and PFBA in the main system; filters certified to NSF/ANSI 53 or 58 for PFOA and PFOS reduction can lower PFAS. On the other hand, no lead service lines reported and no health-based violations since 2016. A water softener is not a filter.Filters that remove PFAS →

Hardness scale

Soft0–60 mg/L0–3.5 gpg
Moderately hard61–120 mg/L3.5–7 gpg
Hard121–180 mg/L7–10.5 gpg
Very hardover 180 mg/Lover 10.5 gpg

What to read next