Water hardness in Washougal, WA

Water in Washougal is soft, with a median of 51 mg/L (3 grains per gallon) across Clark County.

31% softer than the Washington median (74 mg/L) 95th hardest of 122 Washington towns Population 16,985
51mg/L
3 grains per gallon
Soft

There are not enough monitoring sites within 10 miles of Washougal, so this page uses the Clark County median.

Washougal tap water at a glance

Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?

What 51 mg/L means at home

  • Water softener: A water softener is generally not needed. Soft water rarely causes scale.
  • Dishwasher: set the water hardness to about 3 gpg (2.9 °dH), which is the lowest hardness setting (or softener off).
  • Kettles and coffee makers: descaling every 3–6 months is usually enough.
  • Laundry and soap: soap lathers easily and detergent goes further.
  • Water heater: routine flushing every 2–3 years is typically fine.

Where the number comes from

Monitoring sites8
Lab samples111
Sample years2000–2024
Middle 50% of sites19–71 mg/L
Surface water (rivers, lakes)51 mg/L · 8 sites

Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it

Water softener and dishwasher calculator for Washougal

Prefilled with Washougal's measured local hardness of 51 mg/L (3 gpg). If your water bill or utility report gives a different number, enter it instead.

Softener capacity needed (at least)–
Dishwasher setting–set your dishwasher's water hardness to this
Sodium added by softening–

Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter

PFAS in Washougal tap water

City of Washougal is the main public water system for Washougal. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 6 samples taken Aug 2025 – Feb 2026. 3 PFAS were detected. The highest PFOS result was above EPA's drinking water limit (4 ppt).

ChemicalHighest resultDetected inEPA limit
PFOS
perfluorooctane sulfonic acid
7.9 ppt 4 of 6 samples 4 ppt
PFBS
perfluorobutane sulfonic acid
3.3 ppt 3 of 6 samples —
PFPeA
perfluoropentanoic acid
3.1 ppt 1 of 6 samples —

Other water systems serving parts of Washougal

Water systemPFAS detectedHighest PFOA / PFOSTested
Camas Municipal Water Sewer System
serves over 10,000 people
PFOS, PFOA, PFBS 4.4 / 12 ppt Apr 2023 – Oct 2023

What these PFAS levels mean → Which water filters remove PFAS →

Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology

Lead pipes in Washougal

City of Washougal reported 6,040 service lines (the pipes connecting homes to the water main) in its inventory. It reported no lead or galvanized lines requiring replacement.

0lead (0%)
0galvanized requiring replacement
0unknown material (0%)
6,040not lead (100%)

Other water systems serving parts of Washougal

Water systemService linesTotal
Camas Municipal Water Sewer System0 lead · 0 galvanized · 1,378 unknown10,346

How to tell if your home has a lead pipe → Lead pipes in every state →

As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology

Washougal drinking water violations

EPA records show no health-based violations for City of Washougal since 2016.

Other water systems serving parts of Washougal

Water systemHealth-based violationsMonitoring/reporting
Camas Municipal Water Sewer SystemNone25

Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology

Monitoring sites closest to Washougal

SiteTypeDistanceMedianSamplesYears
GIBBONS CREEK AT EVERGREEN HWY, AT WASHOUGAL, WA
USGS Oregon Water Science Center
Stream 1.6 mi19 mg/L102015

Water hardness in towns near Washougal

TownDistanceMedianClass
Camas4 mi 51 mg/LSoft
Orchards12 mi 64 mg/LModerately hard
Vancouver13 mi 74 mg/LModerately hard
Five Corners13 mi 61 mg/LModerately hard
Hazel Dell16 mi 74 mg/LModerately hard
Battle Ground16 mi 41 mg/LSoft
Salmon Creek18 mi 66 mg/LModerately hard
Ridgefield23 mi 53 mg/LSoft
Kelso45 mi 16 mg/LSoft
Longview49 mi 16 mg/LSoft

Clark County

Washougal is in Clark County, where the median is 51 mg/L (soft) across 8 sites.

See all of Clark County →

Washington

The statewide median is 74 mg/L (moderately hard) from 890 sites.

Washington hardness map →

Washougal, WA water: common questions

Do I need a water softener in Washougal?

Probably not. Water measured around Washougal is 3 gpg (51 mg/L, measured locally), under the 7 gpg (120 mg/L) level where scale on fixtures and appliances becomes noticeable.When a softener helps →

Who supplies Washougal's drinking water?

The main public water system serving Washougal in EPA records is City of Washougal. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →

Do I need a water filter in Washougal?

It depends on what you want to remove. In Washougal, EPA testing found PFOS, PFBS and PFPeA in the main system; filters certified to NSF/ANSI 53 or 58 for PFOA and PFOS reduction can lower PFAS. On the other hand, no lead service lines reported and no health-based violations since 2016. A water softener is not a filter.Filters that remove PFAS →

Hardness scale

Soft0–60 mg/L0–3.5 gpg
Moderately hard61–120 mg/L3.5–7 gpg
Hard121–180 mg/L7–10.5 gpg
Very hardover 180 mg/Lover 10.5 gpg

What to read next