Water hardness in Houston, TX

Water in Houston is hard, with a median of 160 mg/L (9.4 grains per gallon) across 48 monitoring sites within 10 miles.

18% softer than the Texas median (194 mg/L) 146th hardest of 251 Texas towns Population 2,314,157
160mg/L
9.4 grains per gallon
Hard

Large city utilities sometimes soften, blend or import water from distant reservoirs, so tap water in Houston can differ from local source water. Your utility's annual Consumer Confidence Report lists the exact tap value.

Houston tap water at a glance

Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?

What 160 mg/L means at home

  • Water softener: Many households here choose a softener to protect water heaters and appliances from scale.
  • Dishwasher: set the water hardness to about 9.4 gpg (9 °dH), which is a medium-to-high hardness setting, with rinse aid.
  • Kettles and coffee makers: descale every 1–2 months with citric acid or vinegar.
  • Laundry and soap: hard water reduces lather, so you may need more detergent, or a softener.
  • Water heater: flush the tank once a year to clear sediment and scale.

Where the number comes from

Monitoring sites48
Lab samples183
Sample years2002–2015
Middle 50% of sites111–218 mg/L
Groundwater (wells, springs)152 mg/L · 36 sites
Surface water (rivers, lakes)211 mg/L · 12 sites

Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it

Water softener and dishwasher calculator for Houston

Prefilled with Houston's measured local hardness of 160 mg/L (9.4 gpg). If your water bill or utility report gives a different number, enter it instead.

Softener capacity needed (at least)–
Dishwasher setting–set your dishwasher's water hardness to this
Sodium added by softening–

Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter

PFAS in Houston tap water

City of Houston is the main public water system for Houston. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 96 samples taken Feb 2023 – Feb 2025. 4 PFAS were detected.

ChemicalHighest resultDetected inEPA limit
6:2 FTS
6:2 fluorotelomer sulfonic acid
42.6 ppt 10 of 96 samples —
PFBA
perfluorobutanoic acid
10.6 ppt 9 of 96 samples —
PFPeA
perfluoropentanoic acid
6.7 ppt 11 of 96 samples —
PFHxA
perfluorohexanoic acid
5.1 ppt 16 of 96 samples —

Other water systems serving parts of Houston

Water systemPFAS detectedHighest PFOA / PFOSTested
Clear Lake City Water Authority
serves over 10,000 people
PFBA, PFHxA, PFPeA +5 more 4 / 6.7 ppt Apr 2023 – Mar 2024
City of Pasadena
serves over 10,000 people
PFBA, PFPeA, PFHxA +4 more ND / 4.9 ppt Mar 2024 – Jan 2026
City of Houston Willow Chase
serves over 10,000 people
None detected — Jan 2024 – Jul 2025
Fort Bend County MUD 30
serves over 10,000 people
PFBA, PFPeA, PFHxA — Feb 2024 – Nov 2024
Harris County FWSD 61
serves over 10,000 people
None detected — Jan 2024 – Jul 2024

What these PFAS levels mean → Which water filters remove PFAS →

Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology

Lead pipes in Houston

City of Houston reported 508,198 service lines (the pipes connecting homes to the water main) in its inventory. It reported no known lead lines, but 427,111 lines are still of unknown material.

0lead (0%)
0galvanized requiring replacement
427,111unknown material (84%)
81,087not lead (16%)

Other water systems serving parts of Houston

Water systemService linesTotal
Clear Lake City Water Authority0 lead · 1 galvanized · 59 unknown17,797
City of Pasadena0 lead · 0 galvanized · 31,648 unknown37,056
City of Houston Willow Chase0 lead · 0 galvanized · 388 unknown604
Fort Bend County MUD 300 lead · 0 galvanized · 0 unknown5,470
Harris County FWSD 610 lead · 0 galvanized · 23 unknown4,136

How to tell if your home has a lead pipe → Lead pipes in every state →

As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology

Houston drinking water violations

EPA records show 1 health-based violation for City of Houston since 2016, all since resolved or closed. The most recent began in May 2025. It also had 1 monitoring or reporting violation (a required test or report was missed or late), which on their own do not mean the water exceeded a limit.

Contaminant or ruleTypeViolationsMost recentStatus
Surface water treatment (filtration/turbidity)
filtration requirements that protect against microbes such as Cryptosporidium
Treatment requirement not met 1 May 2025 Resolved/closed

Other water systems serving parts of Houston

Water systemHealth-based violationsMonitoring/reporting
Clear Lake City Water AuthorityNone2
City of PasadenaNone3
City of Houston Willow ChaseNone0
Fort Bend County MUD 30None4
Harris County FWSD 61None1

Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology

Monitoring sites closest to Houston

SiteTypeDistanceMedianSamplesYears
HUNTING BAYOU AT JENSEN DRIVE
Texas Commission on Environmental Quality
River/Stream 3.1 mi203 mg/L12003
HUNTING BAYOU AT CAVALCADE ST
Texas Commission on Environmental Quality
River/Stream 3.4 mi242 mg/L12003
TRIB OF BUFFALO BAYOU AT EMILE
Texas Commission on Environmental Quality
River/Stream 4.2 mi137 mg/L12002
HUNTING BAYOU AT WIPPRECHT ST
Texas Commission on Environmental Quality
River/Stream 4.2 mi217 mg/L12003
LJ-65-13-226
USGS Texas Water Science Center
Well 4.8 mi424 mg/L22003–2015
LJ-65-21-202
USGS Texas Water Science Center
Well 5.3 mi52 mg/L12010

Water hardness in towns near Houston

TownDistanceMedianClass
West University Place5 mi 157 mg/LHard
Bellaire7 mi 154 mg/LHard
Aldine9 mi 164 mg/LHard
Galena Park10 mi 233 mg/LVery hard
Cloverleaf13 mi 217 mg/LVery hard
South Houston13 mi 164 mg/LHard
Stafford15 mi 154 mg/LHard
Humble16 mi 108 mg/LModerately hard
Pearland16 mi 160 mg/LHard
Channelview16 mi 272 mg/LVery hard

Harris County

Houston is in Harris County, where the median is 143 mg/L (hard) across 237 sites.

See all of Harris County →

Texas

The statewide median is 194 mg/L (very hard) from 2,271 sites.

Texas hardness map →

Houston, TX water: common questions

Do I need a water softener in Houston?

Many homes here use one. Water measured around Houston is 9.4 gpg (160 mg/L, measured locally), above the 7 gpg (120 mg/L) level where scale on fixtures, appliances and water heaters becomes noticeable. For a 3-person home that regenerates weekly, that means a softener of about 17,000 grains.Size it for your household →

Who supplies Houston's drinking water?

The main public water system serving Houston in EPA records is City of Houston. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →

Do I need a water filter in Houston?

It depends on what you want to remove. In Houston, EPA testing found 6:2 FTS, PFBA and PFPeA and 1 other PFAS in the main system; filters certified to NSF/ANSI 53 or 58 for PFOA and PFOS reduction can lower PFAS; the system had 1 health-based violation since 2016, for the Interim Enhanced Surface Water Treatment Rule; the utility's annual report says what was done about it. On the other hand, no lead service lines reported. A water softener is not a filter.Filters that remove PFAS →

Hardness scale

Soft0–60 mg/L0–3.5 gpg
Moderately hard61–120 mg/L3.5–7 gpg
Hard121–180 mg/L7–10.5 gpg
Very hardover 180 mg/Lover 10.5 gpg

What to read next