Water hardness in Wilmington, OH
Water in Wilmington is very hard, with a median of 278 mg/L (16.2 grains per gallon) across 43 monitoring sites within 10 miles.
Wilmington tap water at a glance
- HardnessVery hard (278 mg/L, 16.2 gpg, local measurements). Water softeners are common at this level.Size a water softener →
- PFAS6 found; the highest PFOS result was above EPA's 4 ppt limit (a single result is not a violation).Filters that remove PFAS →
- Lead pipesThe water system reported 161 lead service lines.Check your own pipe →
- ViolationsNo health-based violations since 2016.EPA record →
Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?
What 278 mg/L means at home
- Water softener: Scale build-up is likely. A water softener is commonly used to protect plumbing, water heaters and appliances.
- Dishwasher: set the water hardness to about 16.2 gpg (15.6 °dH), which is a high or maximum hardness setting, with dishwasher salt if your model takes it.
- Kettles and coffee makers: descale every 1–2 months with citric acid or vinegar.
- Laundry and soap: hard water reduces lather, so you may need more detergent, or a softener.
- Water heater: flush the tank once a year to clear sediment and scale.
Size a softener for your home → Hard water and your water heater →
Where the number comes from
Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it
Water softener and dishwasher calculator for Wilmington
Prefilled with Wilmington's measured local hardness of 278 mg/L (16.3 gpg). If your water bill or utility report gives a different number, enter it instead.
Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter
PFAS in Wilmington tap water
Wilmington City PWS is the main public water system for Wilmington. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 4 samples taken Feb 2023 – Nov 2023. 6 PFAS were detected. The highest PFOS result was above EPA's drinking water limit (4 ppt).
| Chemical | Highest result | Detected in | EPA limit |
|---|---|---|---|
| PFPeA perfluoropentanoic acid | 9.8 ppt | 1 of 4 samples | — |
| PFHxA perfluorohexanoic acid | 8.2 ppt | 1 of 4 samples | — |
| PFOS perfluorooctane sulfonic acid | 7.3 ppt | 1 of 4 samples | 4 ppt |
| PFHxS perfluorohexane sulfonic acid | 7 ppt | 1 of 4 samples | 10 ppt* |
| PFBA perfluorobutanoic acid | 5.8 ppt | 1 of 4 samples | — |
| PFHpA perfluoroheptanoic acid | 5 ppt | 1 of 4 samples | — |
Other water systems serving parts of Wilmington
| Water system | PFAS detected | Highest PFOA / PFOS | Tested |
|---|---|---|---|
| Western Water Company serves over 10,000 people | PFOS | ND / 14.1 ppt | Mar 2023 – Jun 2024 |
What these PFAS levels mean → Which water filters remove PFAS →
Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology
Lead pipes in Wilmington
Wilmington City PWS reported 5,143 service lines (the pipes connecting homes to the water main) in its inventory. 161 are lead and 292 are galvanized lines that must be replaced, and 2,822 are still of unknown material.
EPA's 2024 lead rule requires most water systems to replace these lines within 10 years, starting in November 2027 (the rule is being challenged in court). Ask Wilmington City PWS whether your address is on its list.
Other water systems serving parts of Wilmington
| Water system | Service lines | Total |
|---|---|---|
| Western Water Company | 0 lead · 0 galvanized · 0 unknown | 18,179 |
How to tell if your home has a lead pipe → Lead pipes in every state →
As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology
Wilmington drinking water violations
EPA records show no health-based violations for Wilmington City PWS since 2016. It also had 1 monitoring or reporting violation (a required test or report was missed or late), which on their own do not mean the water exceeded a limit.
Other water systems serving parts of Wilmington
| Water system | Health-based violations | Monitoring/reporting |
|---|---|---|
| Western Water Company | None | 5 |
Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology
Monitoring sites closest to Wilmington
| Site | Type | Distance | Median | Samples | Years |
|---|---|---|---|---|---|
| LYTLE CREEK AT WILMINGTON, ADJ TOWNSEND FIELD Division of Surface water (Ohio) (State) | River/Stream | 0.6 mi | 228 mg/L | 6 | 2007–2008 |
| LYTLE CREEK UPST. WILMINGTON @ FIFE AVE. Division of Surface water (Ohio) (State) | River/Stream | 1.1 mi | 177 mg/L | 3 | 2008 |
| LYTLE CREEK AT WILMINGTON @ ST. RT. 730 Division of Surface water (Ohio) (State) | River/Stream | 1.2 mi | 211 mg/L | 3 | 2008 |
| TRIB. TO LYTLE CREEK (5.92) NEAR MOUTH Division of Surface water (Ohio) (State) | River/Stream | 1.4 mi | 278 mg/L | 2 | 2008 |
| TRIB. TO LYTLE CREEK (7.92) AT WILMINGTON @ CEMETERY BRIDGE Division of Surface water (Ohio) (State) | River/Stream | 1.4 mi | 309 mg/L | 2 | 2008 |
| INDIAN RUN S OF WILMINGTON, NEAR MOUTH Division of Surface water (Ohio) (State) | River/Stream | 1.7 mi | 242 mg/L | 6 | 2007–2008 |
Water hardness in towns near Wilmington
| Town | Distance | Median | Class |
|---|---|---|---|
| Xenia | 19 mi | 351 mg/L | Very hard |
| Lebanon | 21 mi | 296 mg/L | Very hard |
| Washington Court House | 22 mi | 308 mg/L | Very hard |
| Centerville | 23 mi | 338 mg/L | Very hard |
| Springboro | 24 mi | 320 mg/L | Very hard |
| Beavercreek | 25 mi | 354 mg/L | Very hard |
| Kettering | 26 mi | 341 mg/L | Very hard |
| Mason | 26 mi | 298 mg/L | Very hard |
| Loveland | 27 mi | 266 mg/L | Very hard |
| Franklin | 27 mi | 330 mg/L | Very hard |
Clinton County
Wilmington is in Clinton County, where the median is 269 mg/L (very hard) across 55 sites.
See all of Clinton County →Wilmington, OH water: common questions
Do I need a water softener in Wilmington?
Very likely. Water measured around Wilmington is 16.2 gpg (278 mg/L, measured locally), above 10.5 gpg (180 mg/L), where softeners are common. For a 3-person home that regenerates weekly, that means a softener of about 28,000 grains.Size it for your household →
Who supplies Wilmington's drinking water?
The main public water system serving Wilmington in EPA records is Wilmington City PWS. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →
Do I need a water filter in Wilmington?
It depends on what you want to remove. In Wilmington, EPA testing found PFPeA, PFHxA and PFOS and 3 other PFAS in the main system; filters certified to NSF/ANSI 53 or 58 for PFOA and PFOS reduction can lower PFAS; the system reports 161 lead service lines; if your home has one, a filter certified to remove lead is the usual step until the line is replaced. On the other hand, no health-based violations since 2016. A water softener is not a filter.Filters that remove PFAS →
Hardness scale
What to read next
- Do you need a water softener?Water here is very hard; size a softener with our calculator.
- Which water filters remove PFAS?EPA tests found 6 PFAS in Wilmington's main water system.
- How to tell if your home has a lead pipe161 lead service lines are reported here.
- Hard water and your water heaterHow scale affects your water heater and how often to flush.