Water hardness in Marietta, OH

Water in Marietta is very hard, with a median of 218 mg/L (12.7 grains per gallon) across 59 monitoring sites within 10 miles.

21% softer than the Ohio median (276 mg/L) 126th hardest of 183 Ohio towns Population 13,090
218mg/L
12.7 grains per gallon
Very hard

Marietta tap water at a glance

Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?

What 218 mg/L means at home

  • Water softener: Scale build-up is likely. A water softener is commonly used to protect plumbing, water heaters and appliances.
  • Dishwasher: set the water hardness to about 12.7 gpg (12.2 °dH), which is a high or maximum hardness setting, with dishwasher salt if your model takes it.
  • Kettles and coffee makers: descale every 1–2 months with citric acid or vinegar.
  • Laundry and soap: hard water reduces lather, so you may need more detergent, or a softener.
  • Water heater: flush the tank once a year to clear sediment and scale.

Where the number comes from

Monitoring sites59
Lab samples306
Sample years2000–2023
Middle 50% of sites168–278 mg/L
Groundwater (wells, springs)279 mg/L · 1 sites
Surface water (rivers, lakes)217 mg/L · 58 sites

Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it

Water softener and dishwasher calculator for Marietta

Prefilled with Marietta's measured local hardness of 218 mg/L (12.7 gpg). If your water bill or utility report gives a different number, enter it instead.

Softener capacity needed (at least)–
Dishwasher setting–set your dishwasher's water hardness to this
Sodium added by softening–

Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter

PFAS in Marietta tap water

Marietta City PWS is the main public water system for Marietta. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 2 samples taken Nov 2024 – Jun 2025. 3 PFAS were detected. The highest PFOS and PFOA results were above EPA's drinking water limit (4 ppt).

ChemicalHighest resultDetected inEPA limit
PFOS
perfluorooctane sulfonic acid
5.6 ppt 2 of 2 samples 4 ppt
PFOA
perfluorooctanoic acid
5.2 ppt 2 of 2 samples 4 ppt
PFBS
perfluorobutane sulfonic acid
4.7 ppt 2 of 2 samples —

Other water systems serving parts of Marietta

Water systemPFAS detectedHighest PFOA / PFOSTested
Putnam Community Water Association PWS
serves 10,000 people or fewer
PFOA, PFHxS 16.9 / ND ppt May 2023 – Nov 2023
Warren Comm W and S ASSN 2
serves 10,000 people or fewer
PFOA, PFBS 20 / ND ppt Apr 2023 – Oct 2023

What these PFAS levels mean → Which water filters remove PFAS →

Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology

Lead pipes in Marietta

Marietta City PWS reported 5,358 service lines (the pipes connecting homes to the water main) in its inventory. 49 are lead and 31 are galvanized lines that must be replaced, and 4,741 are still of unknown material.

49lead (<1%)
31galvanized requiring replacement
4,741unknown material (88%)
537not lead (10%)

EPA's 2024 lead rule requires most water systems to replace these lines within 10 years, starting in November 2027 (the rule is being challenged in court). Ask Marietta City PWS whether your address is on its list.

Other water systems serving parts of Marietta

Water systemService linesTotal
Putnam Community Water Association PWS0 lead · 1 galvanized · 817 unknown970
Warren Comm W and S ASSN 20 lead · 0 galvanized · 0 unknown2,491

How to tell if your home has a lead pipe → Lead pipes in every state →

As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology

Marietta drinking water violations

EPA records show no health-based violations for Marietta City PWS since 2016. It also had 2 monitoring or reporting violations (a required test or report was missed or late), which on their own do not mean the water exceeded a limit.

Other water systems serving parts of Marietta

Water systemHealth-based violationsMonitoring/reporting
Putnam Community Water Association PWSNone4
Warren Comm W and S ASSN 2None3

Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology

Monitoring sites closest to Marietta

SiteTypeDistanceMedianSamplesYears
GOOSE RUN IN MARIETTA, NEAR INTERSECTION BUTLER AVE/4TH ST
Division of Surface water (Ohio) (State)
River/Stream 0.6 mi200 mg/L62012
MUSKINGUM R. AT MARIETTA @ WASHINGTON ST.
Division of Surface water (Ohio) (State)
River/Stream 0.9 mi286 mg/L12006
DUCK CREEK NEAR MARIETTA @ ST. RT. 26
Division of Surface water (Ohio) (State)
River/Stream 1.4 mi325 mg/L52000
DUCK CREEK 0.7 MI. UPST ST. RT. 26, ADJ TWP. RD. 528
Division of Surface water (Ohio) (State)
River/Stream 1.4 mi312 mg/L52000
MUSKINGUM RIVER UPST. UNT @ RM 2.29 S. OF OAK GROVE
Division of Surface water (Ohio) (State)
River/Stream 1.5 mi276 mg/L22016
MUSKINGUM RIVER DST UNT @ RM 2.29 S. OF OAK GROVE
Division of Surface water (Ohio) (State)
River/Stream 1.6 mi278 mg/L22016

Water hardness in towns near Marietta

TownDistanceMedianClass
Athens36 mi 204 mg/LVery hard
Zanesville48 mi 234 mg/LVery hard
Coshocton62 mi 234 mg/LVery hard
Lancaster65 mi 282 mg/LVery hard
Heath67 mi 312 mg/LVery hard
Newark69 mi 295 mg/LVery hard
New Philadelphia73 mi 362 mg/LVery hard
Dover76 mi 361 mg/LVery hard
Pickerington77 mi 328 mg/LVery hard
Steubenville77 mi 566 mg/LVery hard

Washington County

Marietta is in Washington County, where the median is 183 mg/L (very hard) across 126 sites.

See all of Washington County →

Ohio

The statewide median is 276 mg/L (very hard) from 6,849 sites.

Ohio hardness map →

Marietta, OH water: common questions

Do I need a water softener in Marietta?

Very likely. Water measured around Marietta is 12.7 gpg (218 mg/L, measured locally), above 10.5 gpg (180 mg/L), where softeners are common. For a 3-person home that regenerates weekly, that means a softener of about 22,000 grains.Size it for your household →

Who supplies Marietta's drinking water?

The main public water system serving Marietta in EPA records is Marietta City PWS. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →

Do I need a water filter in Marietta?

It depends on what you want to remove. In Marietta, EPA testing found PFOS, PFOA and PFBS in the main system; filters certified to NSF/ANSI 53 or 58 for PFOA and PFOS reduction can lower PFAS; the system reports 49 lead service lines; if your home has one, a filter certified to remove lead is the usual step until the line is replaced. On the other hand, no health-based violations since 2016. A water softener is not a filter.Filters that remove PFAS →

Hardness scale

Soft0–60 mg/L0–3.5 gpg
Moderately hard61–120 mg/L3.5–7 gpg
Hard121–180 mg/L7–10.5 gpg
Very hardover 180 mg/Lover 10.5 gpg

What to read next