Water hardness in London, OH
Water in London is very hard, with a median of 342 mg/L (20 grains per gallon) across 39 monitoring sites within 10 miles.
London tap water at a glance
- HardnessVery hard (342 mg/L, 20 gpg, local measurements). Water softeners are common at this level.Size a water softener →
- PFASNone found in EPA's nationwide testing of the main water system.PFAS results →
- Lead pipesNo known lead lines; 1,128 lines are still of unknown material.Check your own pipe →
- Violations1 health-based violation since 2016.What they were →
Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?
What 342 mg/L means at home
- Water softener: Scale build-up is likely. A water softener is commonly used to protect plumbing, water heaters and appliances.
- Dishwasher: set the water hardness to about 20 gpg (19.2 °dH), which is a high or maximum hardness setting, with dishwasher salt if your model takes it.
- Kettles and coffee makers: descale every 1–2 months with citric acid or vinegar.
- Laundry and soap: hard water reduces lather, so you may need more detergent, or a softener.
- Water heater: flush the tank once a year to clear sediment and scale.
Size a softener for your home → Hard water and your water heater →
Where the number comes from
Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it
Water softener and dishwasher calculator for London
Prefilled with London's measured local hardness of 342 mg/L (20 gpg). If your water bill or utility report gives a different number, enter it instead.
Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter
PFAS in London tap water
London City PWS is the main public water system for London. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 2 samples taken Apr 2023 – Jan 2024. No PFAS were found at or above EPA's minimum reporting levels.
Other water systems serving parts of London
| Water system | PFAS detected | Highest PFOA / PFOS | Tested |
|---|---|---|---|
| Madison County SSWD Water District 1 serves 10,000 people or fewer | None detected | — | Jan 2023 – Jul 2023 |
What these PFAS levels mean → Which water filters remove PFAS →
Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology
Lead pipes in London
London City PWS reported 4,133 service lines (the pipes connecting homes to the water main) in its inventory. 0 are lead and 39 are galvanized lines that must be replaced, and 1,128 are still of unknown material.
EPA's 2024 lead rule requires most water systems to replace these lines within 10 years, starting in November 2027 (the rule is being challenged in court). Ask London City PWS whether your address is on its list.
Other water systems serving parts of London
| Water system | Service lines | Total |
|---|---|---|
| Mid-Ohio WSD Water District 1 | 0 lead · 0 galvanized · 25 unknown | 51 |
How to tell if your home has a lead pipe → Lead pipes in every state →
As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology
London drinking water violations
EPA records show 1 health-based violation for London City PWS since 2016, all since resolved or closed. The most recent began in Jul 2022. It also had 7 monitoring or reporting violations (a required test or report was missed or late), which on their own do not mean the water exceeded a limit.
| Contaminant or rule | Type | Violations | Most recent | Status |
|---|---|---|---|---|
| Coliform bacteria / E. coli (Revised Total Coliform Rule) bacteria that signal possible contamination of the system · what it means | Contaminant above legal limit | 1 | Jul 2022 | Resolved/closed |
Other water systems serving parts of London
| Water system | Health-based violations | Monitoring/reporting |
|---|---|---|
| Madison County SSWD Water District 1 | None | 3 |
Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology
Monitoring sites closest to London
| Site | Type | Distance | Median | Samples | Years |
|---|---|---|---|---|---|
| London Wellfield Division of Drinking and Ground Water (Ohio) | Well | 1 mi | 374 mg/L | 2 | 2012–2014 |
| LONDON WELLFIELD Division of Drinking and Ground Water (Ohio) | Facility Public Water Supply (PWS) | 1 mi | 348 mg/L | 4 | 2000–2005 |
| OAK RUN DST. LONDON CORR. INST. @ OLD SPRINGFIELD RD. Division of Surface water (Ohio) (State) | River/Stream | 1.1 mi | 346 mg/L | 5 | 2011 |
| OAK RUN DST. LONDON @ OLD XENIA RD. Division of Surface water (Ohio) (State) | River/Stream | 2.1 mi | 342 mg/L | 5 | 2011 |
| DEER CREEK NEAR LONDON @ ST. RT. 142 Division of Surface water (Ohio) (State) | River/Stream | 2.5 mi | 263 mg/L | 11 | 2011 |
| DEER CREEK AT LAFAYETTE @ U.S. RT. 40 Division of Surface water (Ohio) (State) | River/Stream | 3.4 mi | 278 mg/L | 5 | 2011 |
Water hardness in towns near London
| Town | Distance | Median | Class |
|---|---|---|---|
| Hilliard | 18 mi | 280 mg/L | Very hard |
| Grove City | 18 mi | 325 mg/L | Very hard |
| Springfield | 19 mi | 356 mg/L | Very hard |
| Upper Arlington | 22 mi | 240 mg/L | Very hard |
| Dublin | 22 mi | 300 mg/L | Very hard |
| Urbana | 22 mi | 365 mg/L | Very hard |
| Marysville | 24 mi | 326 mg/L | Very hard |
| Washington Court House | 25 mi | 308 mg/L | Very hard |
| Columbus | 25 mi | 115 mg/L | Moderately hard |
| Worthington | 26 mi | 237 mg/L | Very hard |
Madison County
London is in Madison County, where the median is 349 mg/L (very hard) across 78 sites.
See all of Madison County →London, OH water: common questions
Do I need a water softener in London?
Very likely. Water measured around London is 20 gpg (342 mg/L, measured locally), above 10.5 gpg (180 mg/L), where softeners are common. For a 3-person home that regenerates weekly, that means a softener of about 35,000 grains.Size it for your household →
Who supplies London's drinking water?
The main public water system serving London in EPA records is London City PWS. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →
Do I need a water filter in London?
It depends on what you want to remove. In London, the system had 1 health-based violation since 2016, for the Revised Total Coliform Rule; the utility's annual report says what was done about it. On the other hand, no PFAS found in EPA testing and no lead service lines reported. A water softener is not a filter.How to read your water quality report →
Hardness scale
What to read next
- Do you need a water softener?Water here is very hard; size a softener with our calculator.
- How to tell if your home has a lead pipe1,128 service lines here are of unknown material.
- Hard water and your water heaterHow scale affects your water heater and how often to flush.
- Water hardness converterConvert mg/L to grains per gallon or °dH for your dishwasher.