Water hardness in Ringwood, NJ
Water in Ringwood is moderately hard, with a median of 90 mg/L (5.2 grains per gallon) across 45 monitoring sites within 10 miles.
Ringwood tap water at a glance
- HardnessModerately hard (90 mg/L, 5.2 gpg, local measurements). Some scale; descale kettles and flush the water heater.Water heater care →
- PFAS8 found; the highest PFOA and PFOS result was above EPA's 4 ppt limit (a single result is not a violation).Filters that remove PFAS →
- Lead pipesNo lead service lines reported.Details →
- Violations4 health-based violations since 2016.What they were →
Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?
What 90 mg/L means at home
- Water softener: Most homes do not need a softener. You may notice light spotting on glass and fixtures.
- Dishwasher: set the water hardness to about 5.2 gpg (5 °dH), which is a low-to-medium hardness setting.
- Kettles and coffee makers: descaling every 3–6 months is usually enough.
- Laundry and soap: soap lathers easily and detergent goes further.
- Water heater: routine flushing every 2–3 years is typically fine.
Where the number comes from
Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it
Water softener and dishwasher calculator for Ringwood
Prefilled with Ringwood's measured local hardness of 90 mg/L (5.3 gpg). If your water bill or utility report gives a different number, enter it instead.
Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter
PFAS in Ringwood tap water
Ringwood Water Department is the main public water system for Ringwood. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 10 samples taken Jan 2025 – Oct 2025. 8 PFAS were detected. The highest PFOA and PFOS results were above EPA's drinking water limit (4 ppt).
| Chemical | Highest result | Detected in | EPA limit |
|---|---|---|---|
| PFOA perfluorooctanoic acid | 12.3 ppt | 10 of 10 samples | 4 ppt |
| PFPeA perfluoropentanoic acid | 9.7 ppt | 4 of 10 samples | — |
| PFOS perfluorooctane sulfonic acid | 8.8 ppt | 10 of 10 samples | 4 ppt |
| PFHxA perfluorohexanoic acid | 8.7 ppt | 4 of 10 samples | — |
| PFBA perfluorobutanoic acid | 5.2 ppt | 2 of 10 samples | — |
| PFBS perfluorobutane sulfonic acid | 5.2 ppt | 6 of 10 samples | — |
| PFHpA perfluoroheptanoic acid | 3.6 ppt | 3 of 10 samples | — |
| PFHxS perfluorohexane sulfonic acid | 3.1 ppt | 2 of 10 samples | 10 ppt* |
What these PFAS levels mean → Which water filters remove PFAS →
Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology
Lead pipes in Ringwood
Ringwood Water Department reported 3,148 service lines (the pipes connecting homes to the water main) in its inventory. It reported no lead or galvanized lines requiring replacement.
How to tell if your home has a lead pipe → Lead pipes in every state →
As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology
Ringwood drinking water violations
EPA records show 4 health-based violations for Ringwood Water Department since 2016, all since resolved or closed. The most recent began in Oct 2024. It also had 25 monitoring or reporting violations (a required test or report was missed or late), which on their own do not mean the water exceeded a limit.
| Contaminant or rule | Type | Violations | Most recent | Status |
|---|---|---|---|---|
| Surface Water Treatment Rule filtration and disinfection of river and lake water | Treatment requirement not met | 2 | Oct 2024 | Resolved/closed |
| Lead and Copper Rule corrosion control, testing and notification requirements for lead | Treatment requirement not met | 2 | Jul 2020 | Resolved/closed |
Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology
Monitoring sites closest to Ringwood
| Site | Type | Distance | Median | Samples | Years |
|---|---|---|---|---|---|
| Ringwood Creek near Wanaque NJ USGS New Jersey Water Science Center | Stream | 1.6 mi | 39 mg/L | 8 | 2012–2014 |
| Blue Mine Brook at Snake Den Road near Wanaque NJ USGS New Jersey Water Science Center | Stream | 3.5 mi | 9 mg/L | 7 | 2017–2019 |
| West Brook near Upper Macopin NJ USGS New Jersey Water Science Center | Stream | 3.7 mi | 54 mg/L | 8 | 2012–2014 |
| 030053-- Dom USGS New Jersey Water Science Center | Well | 4 mi | 41 mg/L | 1 | 2001 |
| Bear Swamp Bk near Oakland NJ USGS New Jersey Water Science Center | Stream | 4.1 mi | 10 mg/L | 8 | 2012–2014 |
| Ramapo River at Glen Gray Road at Oakland NJ USGS New Jersey Water Science Center | Stream | 4.3 mi | 122 mg/L | 8 | 2015–2017 |
Water hardness in towns near Ringwood
| Town | Distance | Median | Class |
|---|---|---|---|
| Wanaque | 4 mi | 96 mg/L | Moderately hard |
| Oakland | 5 mi | 122 mg/L | Hard |
| Pompton Lakes | 7 mi | 110 mg/L | Moderately hard |
| Ramsey | 7 mi | 174 mg/L | Hard |
| Franklin Lakes | 7 mi | 143 mg/L | Hard |
| Waldwick | 10 mi | 178 mg/L | Hard |
| Kinnelon | 10 mi | 86 mg/L | Moderately hard |
| Hawthorne | 12 mi | 177 mg/L | Hard |
| Ridgewood | 12 mi | 170 mg/L | Hard |
| Glen Rock | 13 mi | 180 mg/L | Hard |
Passaic County
Ringwood is in Passaic County, where the median is 82 mg/L (moderately hard) across 34 sites.
See all of Passaic County →New Jersey
The statewide median is 62 mg/L (moderately hard) from 1,612 sites.
New Jersey hardness map →Ringwood, NJ water: common questions
Do I need a water softener in Ringwood?
Probably not. Water measured around Ringwood is 5.2 gpg (90 mg/L, measured locally), under the 7 gpg (120 mg/L) level where scale on fixtures and appliances becomes noticeable. If spotting bothers you, about 9,000 grains of capacity covers a 3-person home between weekly regenerations.Size it for your household →
Who supplies Ringwood's drinking water?
The main public water system serving Ringwood in EPA records is Ringwood Water Department. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →
Do I need a water filter in Ringwood?
It depends on what you want to remove. In Ringwood, EPA testing found PFOA, PFPeA and PFOS and 5 other PFAS in the main system; filters certified to NSF/ANSI 53 or 58 for PFOA and PFOS reduction can lower PFAS; the system had 4 health-based violations since 2016, for the Surface Water Treatment Rule and the Lead and Copper Rule; the utility's annual report says what was done about them. On the other hand, no lead service lines reported. A water softener is not a filter.Filters that remove PFAS →
Hardness scale
What to read next
- Which water filters remove PFAS?EPA tests found 8 PFAS in Ringwood's main water system.
- Water hardness converterConvert mg/L to grains per gallon or °dH for your dishwasher.