Water hardness in Leominster, MA

Water in Leominster is soft, with a median of 12 mg/L (0.7 grains per gallon) across 9 monitoring sites within 10 miles.

77% softer than the Massachusetts median (53 mg/L) 85th hardest of 88 Massachusetts towns Population 43,627
12mg/L
0.7 grains per gallon
Soft

Leominster tap water at a glance

Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?

What 12 mg/L means at home

  • Water softener: A water softener is generally not needed. Soft water rarely causes scale.
  • Dishwasher: set the water hardness to about 0.7 gpg (0.7 °dH), which is the lowest hardness setting (or softener off).
  • Kettles and coffee makers: descaling every 3–6 months is usually enough.
  • Laundry and soap: soap lathers easily and detergent goes further.
  • Water heater: routine flushing every 2–3 years is typically fine.

Where the number comes from

Monitoring sites9
Lab samples104
Sample years2000–2019
Middle 50% of sites10–18 mg/L
Groundwater (wells, springs)158 mg/L · 2 sites
Surface water (rivers, lakes)11 mg/L · 7 sites

Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it

Water softener and dishwasher calculator for Leominster

Prefilled with Leominster's measured local hardness of 12 mg/L (0.7 gpg). If your water bill or utility report gives a different number, enter it instead.

Softener capacity needed (at least)–
Dishwasher setting–set your dishwasher's water hardness to this
Sodium added by softening–

Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter

PFAS in Leominster tap water

Leominster Water Division is the main public water system for Leominster. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 14 samples taken Sep 2023 – Jan 2025. 1 PFAS was detected. The highest PFOA result was above EPA's drinking water limit (4 ppt).

ChemicalHighest resultDetected inEPA limit
PFOA
perfluorooctanoic acid
4.3 ppt 1 of 14 samples 4 ppt

Other water systems serving parts of Leominster

Water systemPFAS detectedHighest PFOA / PFOSTested
Fitchburg DPW, Div. of Water Supply
serves over 10,000 people
PFOA, PFHxA, PFPeA 4.9 / ND ppt Mar 2024 – Dec 2024

What these PFAS levels mean → Which water filters remove PFAS →

Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology

Lead pipes in Leominster

Leominster Water Division has not yet reported its service line inventory to EPA (as of the first quarter of 2026). Ask the utility whether your home's service line has been identified.

Other water systems serving parts of Leominster

Water systemService linesTotal
Fitchburg DPW Division of Water SupplyNot reported—

How to tell if your home has a lead pipe → Lead pipes in every state →

As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology

Leominster drinking water violations

EPA records show 2 health-based violations for Leominster Water Division since 2016, all since resolved or closed. The most recent began in Oct 2018. It also had 1 monitoring or reporting violation (a required test or report was missed or late), which on their own do not mean the water exceeded a limit.

Contaminant or ruleTypeViolationsMost recentStatus
Haloacetic acids (HAA5)
byproducts of chlorine disinfection · what it means
Contaminant above legal limit 2 Oct 2018 Resolved/closed

Other water systems serving parts of Leominster

Water systemHealth-based violationsMonitoring/reporting
Fitchburg DPW, Div. of Water SupplyNone1

Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology

Monitoring sites closest to Leominster

SiteTypeDistanceMedianSamplesYears
MONOOSNOC BROOK, US LEOMINSTER WATER TREATMENT PLT
USGS Massachusetts Water Science Center
Stream 2.5 mi7 mg/L132018–2019
MONOOSNOC BROOK, DS LEOMINSTER WATER TREATMENT PLT
USGS Massachusetts Water Science Center
Stream 2.6 mi9 mg/L112018–2019
WYMAN POND, LEINO PARK RD, DEEP, WESTMINSTER, MA
USGS Massachusetts Water Science Center
Lake, Reservoir, Impoundment 5.4 mi11 mg/L92018–2019
WYMAN POND, LEINO PARK RD, SHALLOW, WESTMINSTER,MA
USGS Massachusetts Water Science Center
Lake, Reservoir, Impoundment 5.4 mi10 mg/L142018–2019
WYMAN POND SHALLOW, WESTMINSTER, MA
USGS Massachusetts Water Science Center
Lake, Reservoir, Impoundment 5.7 mi12 mg/L112018–2019
WYMAN POND DEEP, WESTMINSTER, MA
USGS Massachusetts Water Science Center
Lake, Reservoir, Impoundment 5.7 mi13 mg/L92018

Water hardness in towns near Leominster

TownDistanceMedianClass
Fitchburg6 mi 11 mg/LSoft
Gardner12 mi 11 mg/LSoft
Hudson14 mi 75 mg/LModerately hard
Marlborough16 mi 76 mg/LModerately hard
Maynard17 mi 76 mg/LModerately hard
Worcester17 mi 75 mg/LModerately hard
Framingham23 mi 67 mg/LModerately hard
Lowell24 mi 55 mg/LSoft
Lexington28 mi 80 mg/LModerately hard
Waltham28 mi 80 mg/LModerately hard

Worcester County

Leominster is in Worcester County, where the median is 74 mg/L (moderately hard) across 84 sites.

See all of Worcester County →

Massachusetts

The statewide median is 53 mg/L (soft) from 321 sites.

Massachusetts hardness map →

Leominster, MA water: common questions

Do I need a water softener in Leominster?

Probably not. Water measured around Leominster is 0.7 gpg (12 mg/L, measured locally), under the 7 gpg (120 mg/L) level where scale on fixtures and appliances becomes noticeable.When a softener helps →

Who supplies Leominster's drinking water?

The main public water system serving Leominster in EPA records is Leominster Water Division. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →

Do I need a water filter in Leominster?

It depends on what you want to remove. In Leominster, EPA testing found PFOA in the main system; filters certified to NSF/ANSI 53 or 58 for PFOA and PFOS reduction can lower PFAS; the system had 2 health-based violations since 2016, for Total Haloacetic Acids (HAA5); the utility's annual report says what was done about them. A water softener is not a filter.Filters that remove PFAS →

Hardness scale

Soft0–60 mg/L0–3.5 gpg
Moderately hard61–120 mg/L3.5–7 gpg
Hard121–180 mg/L7–10.5 gpg
Very hardover 180 mg/Lover 10.5 gpg

What to read next