Water hardness in Houma, LA
Water in Houma is hard, with a median of 126 mg/L (7.4 grains per gallon) across 11 monitoring sites within 10 miles.
Houma tap water at a glance
- HardnessHard (126 mg/L, 7.4 gpg, local measurements). Scale on fixtures, kettles and water heaters is likely.Size a water softener →
- PFAS2 found in EPA testing; every result with a federal limit was at or below it.PFAS results →
- Lead pipesNo known lead lines; 3,146 lines are still of unknown material.Check your own pipe →
- Violations1 health-based violation since 2016.What they were →
Choosing a filter? Whole-house vs under-sink · Reverse osmosis · Hot or cold tap water?
What 126 mg/L means at home
- Water softener: Many households here choose a softener to protect water heaters and appliances from scale.
- Dishwasher: set the water hardness to about 7.4 gpg (7.1 °dH), which is a medium-to-high hardness setting, with rinse aid.
- Kettles and coffee makers: descale every 1–2 months with citric acid or vinegar.
- Laundry and soap: hard water reduces lather, so you may need more detergent, or a softener.
- Water heater: flush the tank once a year to clear sediment and scale.
Size a softener for your home → Hard water and your water heater →
Where the number comes from
Measured hardness of local source water (mg/L as calcium carbonate) from Water Quality Portal (USGS, EPA and state agencies). Utilities that soften or blend water may deliver different numbers, so check your utility's Consumer Confidence Report for exact tap values. Methodology · On a private well? How to test it
Water softener and dishwasher calculator for Houma
Prefilled with Houma's measured local hardness of 126 mg/L (7.4 gpg). If your water bill or utility report gives a different number, enter it instead.
Softener sizes assume the EPA average of 82 gallons per person per day; sodium uses about 8 mg/L added per grain removed (University of Nebraska–Lincoln). More: do you need a softener? · softener salt and sodium · hardness converter
PFAS in Houma tap water
Houma Water Treatment Service Area is the main public water system for Houma. EPA's nationwide UCMR 5 study tested it for 29 PFAS ("forever chemicals") in 4 samples taken Jun 2023 – Mar 2024. 2 PFAS were detected.
| Chemical | Highest result | Detected in | EPA limit |
|---|---|---|---|
| PFBA perfluorobutanoic acid | 8 ppt | 4 of 4 samples | — |
| PFPeA perfluoropentanoic acid | 3.7 ppt | 1 of 4 samples | — |
Other water systems serving parts of Houma
| Water system | PFAS detected | Highest PFOA / PFOS | Tested |
|---|---|---|---|
| Lafourche Water District 1 serves over 10,000 people | PFBA | — | Mar 2024 – Dec 2024 |
| Schriever Water Treatment Service Area serves over 10,000 people | PFBA, PFHxA | — | Apr 2023 – Jan 2024 |
What these PFAS levels mean → Which water filters remove PFAS →
Highest single sample in parts per trillion (ppt). Limits apply to yearly averages from 2029, so one high sample is not a violation. *Limit proposed for withdrawal in 2026. ND = not detected. PFAS results for every state · Source: EPA UCMR 5 · Methodology
Lead pipes in Houma
Houma Water Treatment Service Area reported 5,327 service lines (the pipes connecting homes to the water main) in its inventory. It reported no known lead lines, but 3,146 lines are still of unknown material.
Other water systems serving parts of Houma
| Water system | Service lines | Total |
|---|---|---|
| Lafourche Water District 1 | 0 lead · 0 galvanized · 0 unknown | 41,018 |
| Schriever Water Treatment Service Area | 0 lead · 0 galvanized · 32,609 unknown | 45,800 |
How to tell if your home has a lead pipe → Lead pipes in every state →
As reported to EPA (first quarter of 2026). Unknown lines may or may not contain lead; numbers change as utilities inspect lines. Sources: EPA service line inventory · EPA Lead and Copper Rule Improvements · Methodology
Houma drinking water violations
EPA records show 1 health-based violation for Houma Water Treatment Service Area since 2016, all since resolved or closed. The most recent began in Jan 2018. It also had 4 monitoring or reporting violations (a required test or report was missed or late), which on their own do not mean the water exceeded a limit.
| Contaminant or rule | Type | Violations | Most recent | Status |
|---|---|---|---|---|
| Total trihalomethanes (TTHM) byproducts formed when chlorine reacts with natural matter in water · what it means highest measured 81 UG/L; limit 0.080 mg/L | Contaminant above legal limit | 1 | Jan 2018 | Resolved/closed |
Other water systems serving parts of Houma
| Water system | Health-based violations | Monitoring/reporting |
|---|---|---|
| Lafourche Water District 1 | None | 0 |
| Schriever Water Treatment Service Area | None | 5 |
Violations since January 2016, EPA records (2026Q3). A violation is not the same as illness; your utility's annual water quality report explains each one. Violations in every state · Source: EPA ECHO / SDWIS · Methodology
Monitoring sites closest to Houma
| Site | Type | Distance | Median | Samples | Years |
|---|---|---|---|---|---|
| GIWW west of Houma Navigational Canal at Houma, La USGS Louisiana Water Science Center | Stream | 1.2 mi | 11 mg/L | 1 | 2015 |
| Bayou Terrebonne at Houma, Louisiana LDEQ/Water Planning and Assessment (Louisiana) (State) | River/Stream | 1.4 mi | 136 mg/L | 54 | 2007–2024 |
| Houma Navigation Canal East-Northeast of Crozier, Louisiana LDEQ/Water Planning and Assessment (Louisiana) (State) | Canal Drainage | 2.4 mi | 132 mg/L | 46 | 2008–2021 |
| Bayou Grand Caillou South-Southeast of Houma, Louisiana LDEQ/Water Planning and Assessment (Louisiana) (State) | River/Stream | 5.8 mi | 201 mg/L | 58 | 2007–2023 |
| Bayou Black West of Houma, Louisiana LDEQ/Water Planning and Assessment (Louisiana) (State) | River/Stream | 6.2 mi | 90 mg/L | 54 | 2007–2024 |
| Intracoastal Waterway East of Houma, Louisiana LDEQ/Water Planning and Assessment (Louisiana) (State) | Canal Drainage | 6.3 mi | 122 mg/L | 56 | 2007–2024 |
Water hardness in towns near Houma
| Town | Distance | Median | Class |
|---|---|---|---|
| Bayou Cane | 4 mi | 132 mg/L | Hard |
| Bayou Blue | 4 mi | 126 mg/L | Hard |
| Raceland | 11 mi | 84 mg/L | Moderately hard |
| Thibodaux | 16 mi | 123 mg/L | Hard |
| Morgan City | 30 mi | 128 mg/L | Hard |
| Luling | 31 mi | 148 mg/L | Hard |
| Destrehan | 34 mi | 148 mg/L | Hard |
| Laplace | 37 mi | 274 mg/L | Very hard |
| Waggaman | 38 mi | 191 mg/L | Very hard |
| River Ridge | 39 mi | 169 mg/L | Hard |
Terrebonne Parish
Houma is in Terrebonne Parish, where the median is 130 mg/L (hard) across 25 sites.
See all of Terrebonne Parish →Houma, LA water: common questions
Do I need a water softener in Houma?
Many homes here use one. Water measured around Houma is 7.4 gpg (126 mg/L, measured locally), above the 7 gpg (120 mg/L) level where scale on fixtures, appliances and water heaters becomes noticeable. For a 3-person home that regenerates weekly, that means a softener of about 13,000 grains.Size it for your household →
Who supplies Houma's drinking water?
The main public water system serving Houma in EPA records is Houma Water Treatment Service Area. Some neighborhoods may be served by a different system, so check the name on your water bill.How we match towns to water systems →
Do I need a water filter in Houma?
It depends on what you want to remove. In Houma, EPA testing found PFBA and PFPeA in the main system; filters certified to NSF/ANSI 53 or 58 for PFOA and PFOS reduction can lower PFAS; the system had 1 health-based violation since 2016, for TTHM; the utility's annual report says what was done about it. On the other hand, no lead service lines reported. A water softener is not a filter.Filters that remove PFAS →
Hardness scale
What to read next
- Do you need a water softener?Water here is hard; size a softener with our calculator.
- Which water filters remove PFAS?EPA tests found 2 PFAS in Houma's main water system.
- How to tell if your home has a lead pipe3,146 service lines here are of unknown material.
- TTHM in drinking waterDisinfection byproducts appear in this system's violation record.